During DPF regeneration the Aftertreatment Fuel Pressure Sensor monitors the fuel pressure rise and drop in the Aftertreament Hydrocarbon Dosing Module. During Air Purge the Aftertreatment Fuel Pressure Sensor monitors the air pressure rise and drop in the Aftertreament Hydrocarbon Dosing Module. The Engine Control Module (ECM) uses this input to determine if the system is operating correctly.
Conditions for diagnostic trouble code (DTC):
1) The sensor signal is not rational
2) Aftertreatment fuel pressure below Placeholder, aftertreatment fuel shutoff valve open
Observable symptoms
1) Regeneration not possible
2) Regeneration aborted
Probable cause
1) Air in the fuel system
2) Aftertreatment fuel shut-off valve, Stuck in one position
3) Fuel filter
4) De-aeration valve
5) Overflow valve
6) Fuel pump
Detailed information
1) This DTC will only set during an aftertreatment DPF service regeneration
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5
-
Volvo All Engines (2004 Emissions) Fault Code: PID 190 FMI 0 Engine Oil Level / Temperature Sensor
All Engines (2004 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P100587 PID: EMS Pedal Message
All Engines (2013 Emissions) -
Volvo All Engines (2004 Emissions) Fault Code: SID 39 FMI 14 Starter Output
All Engines (2004 Emissions) -
Volvo All Engines (2004 Emissions) Fault Code: PID 110 FMI 0 Engine Coolant Temperature Sensor
All Engines (2004 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P027000 PID: EMS Cylinder 4 Injector Circuit Low
All Engines (2013 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P040964 PID: EMS EGR Differential Pressure Sensor
All Engines (2013 Emissions)