The aftertreatment control module (ACM) supplies a pulsed ground signal to activate the ignition coil. The ignition coil is connected to the ignition electrodes by two ignition wires. When activated it supplies 40,000 to 45,000 volts to the ignition electrodes creating an arc that ignites the atomized fuel and air mixture in the aftertreatment diesel particulate filter (DPF) combustion chamber of the aftertreatment DPF.
Conditions for diagnostic trouble code (DTC):
1) Pin: 21 (Ground wire), Current below normal or open circuit
Observable symptoms
1) Regeneration not possible
Probable cause
1) Wiring harness between Aftertreatment ignition coil and Aftertreatment Control Module (ACM)
2) Aftertreatment ignition coil
3) Aftertreatment Control Module (ACM)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0100 Lost Communication With ECM A
1000 & 2000 Gen 5
-
Volvo All Engines (2013 Emissions) Fault Code: P065111 PID: EMS Sensor Reference Voltage “B”
All Engines (2013 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P255612 PID: EMS Engine Coolant Level Sensor/Switch
All Engines (2017 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P009E73 PID: EMS Fuel Pressure Relief Control Performance / Stuck Off
All Engines (2013 Emissions) -
Volvo All Engines (2010 Emissions) Fault Code: SPN 103 FMI 15 PID: Engine Turbocharger – Least Severe Level
All Engines (2010 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P114970 PID: EMS Intake Air Heater “B” Circuit
All Engines (2017 Emissions) -
Volvo All Engines (2010 Emissions) Fault Code: SPN 100 FMI 18 PID: 100 Engine Oil Pressure – Moderately Severe Level
All Engines (2010 Emissions)