Volvo All Engines (2010 Emissions) Fault Code: SPN 3485 FMI 10 PID: Aftertreatment DPF Atomization Air Pressure

The aftertreatment diesel particulate filter (DPF) atomization air pressure sensor is used to monitor the pressure of the compressed air supply to the aftertreatment DPF atomization module during active diagnostics and measures the combined atomization fuel and air pressure during burner operation. The sensor consists of a pressure sensitive diaphragm/amplifier sensor. Air pressure causes the sensors diaphragm to deflect and produce an electrical signal proportional to the pressure. The diaphragm deflection signal is amplified in the sensor.

Conditions for diagnostic trouble code (DTC):
1) Low air pressure check failed during active diagnostics check of the air bleed orifice on the aftertreatment diesel particulate filter (DPF) atomization module

Observable symptoms
1) Regeneration not possible

Probable cause
1) Aftertreatment Diesel Particulate Filter (DPF) Atomization Module (Internal air bleed orifice)
2) Low air pressure
3) Aftertreatment DPF Atomization Air Pressure Sensor

Reviews

There are no reviews yet.

Be the first to review “Volvo All Engines (2010 Emissions) Fault Code: SPN 3485 FMI 10 PID: Aftertreatment DPF Atomization Air Pressure”

Your email address will not be published. Required fields are marked *