The aftertreatment diesel particulate filter (DPF) atomization air pressure sensor is used to monitor the pressure of the compressed air supply to the aftertreatment DPF atomization module during active diagnostics and measures the combined atomization fuel and air pressure during burner operation. The sensor consists of a pressure sensitive diaphragm/amplifier sensor. Air pressure causes the sensors diaphragm to deflect and produce an electrical signal proportional to the pressure. The diaphragm deflection signal is amplified in the sensor.
Conditions for diagnostic trouble code (DTC):
1) Atomization air pressure above normal value with aftertreatment diesel particulate filter (DPF) air shutoff valve closed and aftertreatment DPF atomization air valve open during active diagnostics
Observable symptoms
1) Regeneration not possible
Probable cause
1) Aftertreatment Diesel Particulate Filter (DPF) Atomization Module (Diesel Particulate Filter (DPF) Air shutoff Valve)
2) Aftertreatment DPF Atomization Air Pressure Sensor
3) Aftertreatment Diesel Particulate Filter (DPF) Atomization Module (Aftertreatment DPF Atomization Air Actuator)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2764 TCC PCS Control Circuit Low
1000 & 2000 Gen 5
-
Volvo All Engines (2017 Emissions) Fault Code: P009011 PID: EMS Fuel Pressure Regulator 1 Control
All Engines (2017 Emissions) -
Detroit DD16 EPA07 (2007-09) Fault Code: SPN 711 FMI 4 (CPC) Short to Ground
DD16 EPA07 (2007-09) -
Volvo All Engines (2017 Emissions) Fault Code: P20C113 PID: ACM Reductant Heater “C” Control
All Engines (2017 Emissions) -
Allison 3000 & 4000 Gen 4 Fault Code: P0733 Incorrect 3rd Gear Ratio
3000 & 4000 Gen 4 -
PACCAR MX (2004 Emissions) Fault Code: P1601 PCI ECU – Internal Error
MX (2004 Emissions) -
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 91 FMI 4 (CPC) Circuit Failed Low
DD13 EPA07 (2007-09)