The atomization air valve is part of the atomization module and the combustion air valve is located on the engine. Both are controlled by the same DPF ECU output. The valves are normally closed and are opened when voltage is supplied by the DPF ECU. When opened, compressed air supplied from the air tank through the priority valve is supplied through the atomization air valve to the atomization nozzle while charged air from the intake manifold is supplied through the combustion air valve to the DPF Unit combustion chamber.
Conditions for diagnostic trouble code (DTC):
1) The voltage at pin A118.B:D3 is below normal value
Observable symptoms
1) Regeneration aborted
2) Regeneration not possible
Probable cause
1) Wiring harness between Aftertreatment Diesel Particulate FIlter (DPF) Combustion Air Valve and Aftertreatment Control Module (ACM)
2) Aftertreatment Diesel Particulate Filter (DPF) Atomization Module
3) Aftertreatment Diesel Particulate FIlter (DPF) Combustion Air Valve
4) DPF Control Unit
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5
-
Volvo All Engines (2013 Emissions) Fault Code: P20B300 PID: EMS Reductant Heater Coolant Control Valve Circuit Low
All Engines (2013 Emissions) -
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 1624 FMI 9 (CPC) Message is Missing
DD15 EPA10 (2010-13) -
Volvo All Engines (2017 Emissions) Fault Code: P226413 PID: EMS Water in Fuel Sensor
All Engines (2017 Emissions) -
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 709 FMI 4 (MCM, CPC) Short to Ground
DD16 GHG14 (2014-16) -
Volvo All Engines (2013 Emissions) Fault Code: P040371 PID: EMS EGR “A” Control
All Engines (2013 Emissions) -
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3510 FMI 3 (CPC) High Voltage
DD13 EPA07 (2007-09)