The Aftertreatment Hydrocarbon Dosing Module contains three non serviceable valves, the Aftertreatment Fuel Shutoff Valve, Aftertreatment Purge Air Valve and Aftertreatment Hydrocarbon Dosing Valve, and a serviceable Aftertreatment Fuel Pressure Sensor.
During Air Purge operation the Engine Control Module (ECM) sends a voltage signal to activate the Aftertreatment Purge Air Valve open. This allows air pressure to flow into the Aftertreament Hydrocarbon Dosing Module. The ECM then sends a PWM signal to the Aftertreatment Hydrocarbon Dosing Valve that allows purge air pressure to be monitored by a signal from the Aftertreatment Fuel Pressure Sensor to the ECM.
Conditions for diagnostic trouble code (DTC):
1) Voltage above normal or shorted high
Diagnostic operating conditions
1) Output activated
Observable symptoms
1) Regeneration not possible
Probable cause
1) Connector
2) Engine wiring harness
3) Aftertreatment Hydrocarbon Dosing Module
4) Engine control module (ECM)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5
-
Volvo All Engines (2013 Emissions) Fault Code: P028A1C PID: EMS Charge Air Cooler Cooling Fan Control
All Engines (2013 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P222612 PID: EMS Barometric Pressure Circuit
All Engines (2013 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P20A000 PID: ACM Reductant Purge Control Valve
All Engines (2017 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P20B900 PID: ACM Reductant Heater “A” Control
All Engines (2013 Emissions)