Volvo All Engines (2010 Emissions) Fault Code: SPN 4334 FMI 5 PID: PPID 273 Aftertreatment 1 SCR Dosing Reagent Absolute Pressure
The aftertreatment control module (ACM) uses the aftertreatment diesel exhaust fluid (DEF) dosing pressure sensor value to adjust and maintain DEF pressure at the DEF dosing valve by controlling DEF pump speed. If the pressure decreases below expected value when the pump is in initial pressure build-up mode or if the pressure increases above expected value when pump is in idle speed mode, the ACM considers DEF pressure outside of normal operating range and indicates a malfunction in a DEF dosing pressure sensor.
Conditions for diagnostic trouble code (DTC):
1) The voltage at pin A137:30 is more than 4.75?V
Observable symptoms
1) No aftertreatment diesel exhaust fluid (DEF) dosage
Probable cause
1) Open circuit, Signal wire
2) Open circuit, Ground wire
3) Short circuit to voltage supply, Signal wire
4) Short circuit to 5V, Signal wire
5) Wiring harness
6) Aftertreatment Diesel Exhaust Fluid (DEF) Pump
7) Aftertreatment Control Module (ACM)
Detailed information
1) Possible engine de-rate
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2764 TCC PCS Control Circuit Low
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5
-
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 97 FMI 15 (MCM) Water-In-Fuel Warning
DD13 EPA10 (2010-13) -
CAT 3406E (Prefix 1MM or 2WS) Fault Code: 24 PID: SPN: 100 FMI: 3 Oil Pressure voltage high
3406E (Prefix 1MM or 2WS) -
Allison 1000 & 2000 Gen 4 Fault Codes: P0845 Transmission Pressure Switch Solenoid D Circuit
1000 & 2000 Gen 4 $50.00 -
Volvo All Engines (2017 Emissions) Fault Code: P02E900 PID: EMS Diesel Intake Air Flow Position Sensor Circuit High
All Engines (2017 Emissions)