Cummins ISL CM850 (2003-06) Fault Code: 1716 PID: SPN: 411 FMI: 11 Auxiliary Temperature Sensor Input 1 Circuit – Root Cause Not Known. High temperature detected by the OEM temperature sensor or by the engine coolant temperature sensor.
Cummins ISL CM850 (2003-06) Fault Code: 1716 PID: SPN: 411 FMI: 11 Auxiliary Temperature Sensor Input 1 Circuit – Root Cause Not Known. High temperature detected by the OEM temperature sensor or by the engine coolant temperature sensor.
This fault code indicates that coolant temperature has exceeded the engine protection limits for high coolant temperature.
On-Board Diagnostics (OBD) information:
1)The ECM illuminates the appropriate amber or red fault lamp when the diagnostic runs and fails
2)The ECM turns off the appropriate fault lamp when the diagnostic runs and passes.
Possible repairs:
1)Replace the ECM.
2)Replace the OEM harness.
-
DETROIT DDDL 8.14 SP3 – Detroit Diesel Diagnostic Link 8.14 SP3 2021 ( 1PC )
Detroit $73.00Rated 0 out of 5 -
John Deere & Hitachi Parts ADVISOR 2020 [08.2020] Offline DVD Spare Parts Catalog
John Deere $120.00Rated 0 out of 5 -
PF Diagnose 2.0.2.23 Diagnostics Software 2013 – Full Heavy & Medium Duty with OBDII Support – Online Installation Service
PF Diagnose $60.00Rated 0 out of 5
-
10 IN 1 FOR CAT SIS Caterpillar 2021 Full Service Dealer INCLUDING CAT 2019 C
CAT $110.00Rated 0 out of 5 -
volvo Devtool Studio V2 / V3 / V4 Developer tool plus 2.6 / 2.7
Trucks software $35.00Rated 0 out of 5 -
download MANCATS II v14.01 2014 Diagnostic software MAN CATS ( virtual machine )
MAN $75.00Rated 0 out of 5
Related products
-
SERVICE MANUAL Eaton Fuller® HD FR/FRO TransmissionsTRSM2400April 2013
TRUCK MANUALSRated 0 out of 5