PACCAR MX (2004 Emissions) Fault Code: U1802 VTG Turbocharger Actuator Power Supply – Data Valid but Too High
PACCAR MX (2004 Emissions) Fault Code: U1802 VTG Turbocharger Actuator Power Supply – Data Valid but Too High
SET CONDITIONS:
The VTG turbo charger actuator (L037) detects that the actuator power supply is above 17 volts for more than 40 seconds.
DIAGNOSTIC CONDITION:
This diagnostic runs continuously when the ignition is on.
CORRESPONDING OBD READINESS MONITOR:
None
RESET CONDITION:
This DTC changes to inactive after the ignition is keyed off and keyed on again and the fault is no longer detected.
REPAIR VERIFICATION:
1. Clear all DTCs.
2. Test drive or operate the vehicle to meet the diagnostic conditions and set conditions.
3. Did the DTC come back?
– No, repair successful
– Yes, repair unsuccessful
POSSIBLE CAUSES:
1. VTG turbocharger actuator power supply, check:
– Whether more ECUs on the vehicle detect incorrect power supply
– Battery voltage (faulty alternator)
– VTG turbocharger actuator power supply
2. Faulty VTG turbo charger actuator if the DTC remains active after the above is performed/checked
ADDITIONAL INFORMATION:
The power supply of the actuator is continuously monitored.
-
Wabco ToolBox plus 13.7 + ECAS CAN2 v3.00 Diagnostics Software
Trucks software $84.00Rated 0 out of 5 -
DOWNLOAD NISSAN UD DIESEL PC-CONSULT DIAGNOSTIC 1.1.13 & PC-REPROMASTER 1.2.0
NISSAN UD $100.00Rated 0 out of 5 -
ddct Detroit diesel calibration tool (DDCT) v4.5 English Include Calibrations & Metafiles
Detroit $30.00Rated 0 out of 5 -
Hino Diagnostic eXplorer 2 – Hino DX2 v1.1.21.4 with keygen unlocked ( Hino trucks )
Hino $60.00Rated 0 out of 5
Related products
-
SERVICE MANUAL International Engines DT466 & DT570 (2004-2006) D
INTERNATIONAL ENGINES $34.00Rated 0 out of 5 -
SERVICE MANUAL International Engines DT466 & DT530 (1999-2000) B
INTERNATIONAL ENGINES $29.00Rated 0 out of 5 -
SERVICE MANUAL International Engines MaxxForce 5 (2007 & 2009)
INTERNATIONAL ENGINES $25.00Rated 0 out of 5