This diagnostic function indicates malfunction at the exhaust gas temperature (EGT) sensor. The purpose of the exhaust gas sensor is to contribute the relevant temperatures required for the temperature regulated aftertreatment diesel particulate filter regeneration control. A faulty EGT sensor can result with a failed aftertreatment (DPF) regeneration.
Conditions for diagnostic trouble code (DTC):
1) Exhaust temperature, Lower than expected
Observable symptoms
1) This function indicates that the NOx conversion efficiency is not correct
Probable cause
1) Aftertreatment exhaust gas temperature (EGT) sensors installed in the incorrect location on the aftertreatment diesel particulate filter (DPF)
2) Low compression
3) Pre-catalyst, Exhaust Gas Temperature (EGT) Sensor
4) Exhaust system
5) Fan
6) Aftertreatment Hydrocarbon Doser
7) Aftertreatment selective catalytic reduction (SCR) catalyst
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0100 Lost Communication With ECM A
1000 & 2000 Gen 5
-
Volvo All Engines (2013 Emissions) Fault Code: P20BA00 PID: ACM Reductant Heater “A” Control Performance
All Engines (2013 Emissions) -
Volvo All Engines (2010 Emissions) Fault Code: SPN 655 FMI 12 PID: SID 5 Engine Injector Cylinder 5
All Engines (2010 Emissions) -
Volvo All Engines (2010 Emissions) Fault Code: SPN 677 FMI 5 PID: SID 39 Engine Starter Motor Relay
All Engines (2010 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P24D100 PID: EMS Particulate Matter Sensor Regeneration Incomplete
All Engines (2013 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P260011 PID: EMS Coolant Pump “A” Control
All Engines (2017 Emissions)