This diagnostic function indicates malfunction at the exhaust gas temperature (EGT) sensor. The purpose of the exhaust gas sensor is to contribute the relevant temperatures required for the temperature regulated aftertreatment diesel particulate filter regeneration control. A faulty EGT sensor can result with a failed aftertreatment (DPF) regeneration.
Conditions for diagnostic trouble code (DTC):
1) Exhaust temperature, Lower than expected
Observable symptoms
1) This function indicates that the NOx conversion efficiency is not correct
Probable cause
1) Aftertreatment exhaust gas temperature (EGT) sensors installed in the incorrect location on the aftertreatment diesel particulate filter (DPF)
2) Low compression
3) Pre-catalyst, Exhaust Gas Temperature (EGT) Sensor
4) Exhaust system
5) Fan
6) Aftertreatment Hydrocarbon Doser
7) Aftertreatment selective catalytic reduction (SCR) catalyst
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0100 Lost Communication With ECM A
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2764 TCC PCS Control Circuit Low
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5
-
Volvo All Engines (2013 Emissions) Fault Code: P111E00 PID: EMS Engine Coolant Temperature Moderately High
All Engines (2013 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P245213 PID: ACM Particulate Filter Pressure Sensor “A”
All Engines (2013 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P065800 PID: EMS ACM Actuator High Supply 1 Short Circuit Low
All Engines (2013 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P25AE00 PID: EMS Piston Cooling Oil Pressure Too Low
All Engines (2013 Emissions)