The aftertreatment diesel particulate filter (DPF) combustion air valve is controlled by the aftertreatment control module (ACM) output. The combustion air valve is normally closed and is opened when a ground signal is supplied by the ACM to the combustion air valve solenoid. When opened, charged air from the intake manifold is supplied through the combustion air valve to the aftertreatment DPF combustion chamber.
Conditions for diagnostic trouble code (DTC):
1) The voltage at pin A137:33 is above normal value
Diagnostic operating conditions
1) Ignition key in ON position
Observable symptoms
1) Regeneration not possible
Probable cause
1) Short circuit to voltage supply, Control wire (-)
2) Connector
3) Aftertreatment diesel particulate filter (DPF) wiring harness, below raceway
4) Chassis Harness
5) Aftertreatment DPF Combustion Air Solenoid
6) Aftertreatment Control Module (ACM)
-
2021 VOLVO PREMIUM TECH TOOL PTT V2.8.21 VCADS+DEVELOPER TOOL+APCI 2021/09 ( 1 PC )
Trucks software $85.00
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5
-
Volvo All Engines (2010 Emissions) Fault Code: SPN 655 FMI 7 PID: SID 5 Engine Injector Cylinder 5
All Engines (2010 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P019511 PID: EMS Engine Oil Temperature Sensor “A”
All Engines (2013 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P008800 PID: EMS Fuel Rail/System Pressure – Too High Bank 1
All Engines (2013 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P113712 PID: EMS Oil Thermostat
All Engines (2013 Emissions)