Cummins ISL CM850 (2003-06) Fault Code: 2555 PID: SID 70 SPN: 729 FMI: 3 Intake Air Heater #1 Circuit – Voltage Above Normal or Shorted to High Source. High voltage detected at the intake air heater signal circuit.
Cummins ISL CM850 (2003-06) Fault Code: 2555 PID: SID 70 SPN: 729 FMI: 3 Intake Air Heater #1 Circuit – Voltage Above Normal or Shorted to High Source. High voltage detected at the intake air heater signal circuit.
Possible causes:
1)Intake air heater relay signal wire not connected to the relay
2)Intake air heater relay return wire not connected to the relay
3)Open circuit in the intake air heater relay signal wire
4)Open circuit in the intake air heater relay return wire
5)Intake air heater signal wire shorted to a voltage source.
Possible repairs:
1)Flush the dirt, debris, or moisture from the connector pins.
2)Install the appropriate connector seal if it is damaged or missing.
2)Replace the intake air heater relay.
4)Replace the OEM harness
5)The removal and installation of the connector may correct the fault.
6)Replace the ECM.
-
Navistar international OnCommand service information 2018 software trucks
Navistar $50.00Rated 0 out of 5
-
Volvo Impact 2021 Trucks & Buses 06.2021 DVD 9116 Spare Parts Catalog
Trucks software $55.00Rated 0 out of 5 -
Eaton Service Ranger 4.9 Engineering 4.9 [05.2021] Engineering Level ( 1 PC )
Eaton $67.00Rated 0 out of 5 -
DETROIT DDDL 8.14 SP3 – Detroit Diesel Diagnostic Link 8.14 SP3 2021 ( 1PC )
Detroit $73.00Rated 0 out of 5 -
Navistar international OnCommand service information 2018 software trucks
Navistar $50.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2730 Pressure Control Solenoid 1 (PCS1) Control Circuit – High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2685 Actuator Supply Circuit Voltage 3 Low (HSD3)
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2671 Actuator Supply Voltage 2 (HSD2) – High (Batt)
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2670 Actuator Supply Voltage 2 (HSD2) – Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P097B Shift Solenoid 2 (SS2) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2637 Torque Management Feedback Signal – SEM
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P097C Shift Solenoid 3 (SS3) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P097A Shift Solenoid 1 (SS1) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2727 Pressure Control Solenoid 1 (PCS1) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2724 Pressure Control Solenoid 1 (PCS1) – Stuck On
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0100 Lost Communication With ECM A
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2729 Pressure Control Solenoid 1 (PCS1) Control Circuit – Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2669 Actuator Supply Voltage 2 Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P1790 Gear Shift Module 1 Calibration Invalid
1000 & 2000 Gen 5Rated 0 out of 5
-
Allison Transmission – WTEC 2 MD/HD/B SERIES TRANSMISSIONS
Allison$20.00Original price was: $20.00.$16.00Current price is: $16.00.Rated 0 out of 5 -
SERVICE MANUAL International Engines DT466 & DT530 (2001-2003) C
INTERNATIONAL ENGINES $31.00Rated 0 out of 5